Salt spray test chamber requirements for different standards for salt solution

The salt solution is a key element of the salt spray test chamber test and plays a decisive role in the damage of the sample. The requirements for salt solutions are mainly:

1) Salt solution preparation materials - water and sodium chloride requirements;

2) the concentration of the salt solution;

3) the pH of the salt solution;

There are different requirements for salt spray test salt solutions in different standards of salt spray test chamber, see the following table:

project

GJB150.11

GJB150.11A

GB/T2423.17

GB/T2423.18

GB/T10125

GB/T1771

ASTM B117

water

Distilled or deionized water with a resistivity of not less than 50,000 Ω·cm

The resistivity is 1500~2500Ω·m

Distilled or deionized water

Distilled or deionized water with a resistivity of 20 μS / cm

GB/T6682 tertiary water (conductivity ≤0.5Ms/m)

ASTM D1193 four-stage water (conductivity ≤5.0μS/cm)

Sodium chloride

Chemically pure

w(Nal)≤0.1%

Total impurity ≤0.5%

w(Nal)≤0.1%

Total impurity ≤0.3%

Chemically pure

w(Nal)≥99.5%, w(Nal)≤0.1%, basically free of Cu, Ni

Halides other than Cl ≤ 0.1%, total impurities ≤ 0.3%, w (Cu) < 3 × 10 (-6th power)

Quality score

5% ± 1%

-

5% ± 1%

Concentration

-

(50±5)g/L

(50±5)g/L

-

pH

(35 ± 2) °C is 6.5 ~ 7.2

(20±2) °C is 6.5~7.2

6.5~7.2

(35 ± 2) °C is 6.5 ~ 7.2

Note: 1. GB/T6682 three-stage water requirement, pH is 5.0-7.5, conductivity ≤0.5mS/m, oxidizable substance (in O) <0.4mg/L, (105°C±2°C), evaporation Residue ≤ 2.0 mg / L.

2. ASTM D1193 four-stage water requirement, pH 5-8 at 25 °C, maximum resistivity 5.0 μS/cm, maximum water resistivity 2000 Ω•m, maximum sodium content 50 μg/L.

3. The sodium chloride solution having a relative density of 1.0255 to 1.0400 at 25 ° C satisfies the requirement of (50 ± 5) g / L or 5% ± 1%.